Reference and Sources: VLB=VESA Local Bus. This file is intended to provide a basic functional overview of the Vesa Local Bus, so that hobbyists and amateurs can design their own VLB compatible cards. It is not intended to provide complete coverage of the VLB standard. VLB Connectors are usually inline with ISA connectors, so that adapter cards may use both. However, the VLB is separate, and does not need to connect to the ISA portion of the bus. The 64 bit expansion of the bus (optional) does not add additional pins or connectors. Instead, it multiplexes the existing pins. The 32 bit VLB bus does not use the 64 bit signals shown in the above pinouts. (At the card) 58 PIN EDGE CONNECTOR MALE at the card.
Signal DescriptionsA2-A31Address Bus ADSAddress Strobe BE0-BE3Byte Enable. Indicates that the 8 data lines corresponding to each signal will deliver valid data. BLASTBurst Last. Indicates a VLB Burst Cycle, which will complete with *BRDY. The VLB Burst cycle consists of an address phase followed by four data phases. BRDYBurst Ready. Indicates the end of the current burst transfer. D0-D31Data Bus. Valid bytes are indicated by *BE(x) signals. D/CData/Command. Used with M/IO and W/R to indicate the type of cycle.
ID0-ID4Identification Signals.
IRQ9Interrupt Request. Connected to IRQ9 on ISA bus. This allows standalone VLB adapters (not connected to ISA portion of the bus) to have one IRQ. LEADSLocal Enable Address Strobe. Set low by VLB master (not CPU). Also used for cache invalidation signal. LBS16Local Bus Size 16. Used by slave device to indicate that it has a transfer width of only 16 bits. LCLKLocal Clock. Runs at the same frequency as the cpu, up to 50 MHz. 66 MHz is allowed for on-board devices. LDEVLocal Device: When appropriate address and M/IO signals are present on the bus, the VLB device must pull this line low to indicate that it is a VLB device. The VLB controller will then use the VLB bus for the transfer. LRDYLocal Ready. Indicates that the VLB device has completed the cycle. This signal is only used for single cycle transfers. *BRDY is used for burst transfers. LGNTLocal Grant. Indicates that an *LREQ signal has been granted, and control is being transferred to the new VLB master. LREQLocal Request. Used by VLB Master to gain control of the bus. M/IOMemory/IO. See D/C for signal description. RDYRTNReady Return. Indicates VLB cycle has been completed. May precede LRDY by one cycle. RESETReset. Resets all VLB devices. WBACKWrite Back. 64-bit Expansion SignalsACK64Acknowledge 64 bit transfer. Indicates that the device can perform the requested 64 bit transfer cycle. BE4-BE7Byte Enable. Indicates which bytes are valid (similar to BE0-BE3). D32-D63Upper 32 bits of data bus. Multiplexed with address bus. LBS64Local Bus Size 64 bits. Used by VLB Master to indicate that it desires a 64 bit transfer. W/RWrite/Read. See D/C for signal description. 64 Bit Data Transfer Timing Diagram:Address Data Phase Phase _______ _______ _______ LCLK ___| |_______| |_______| |_______ ____ ______________________________________ *ADS |_______| _______________ _______________ A2-A31 ----<_______________><_______________>------------- D34-D63 Address Data D34-D63 _______________ _______________ D/C ----<_______________><_______________>------------- M/IO, W/R M/IO, W/R Data D32-33 _____ _____________________________ *LDEV |_______________| _____ _____________________________ *LBS64 |_______________| ______ _____________________________ *ACK64 |______________| _______________ D0-D31 --------------------<_______________>------------- _____________________ _____________ LRDY |______________| |