Reference and Sources: Seems to be available on some Future Domain SCSI-controllers only. (At the controller)
(At the cable) 25 PIN D-SUB FEMALE at the controller. 25 PIN D-SUB MALE at the cable. Pin | Name | Dir | Description | 1 | GND | ------ | Ground | 2 | DB1 | IN/OUT | Data Bus 1 | 3 | DB3 | IN/OUT | Data Bus 3 | 4 | DB5 | IN/OUT | Data Bus 5 | 5 | DB7 | IN/OUT | Data Bus 7 | 6 | GND | ------ | Ground | 7 | /SEL | IN/OUT | Select | 8 | GND | ------ | Ground | 9 | TMPWR | IN/OUT | Termination Power | 10 | /RST | IN/OUT | Reset | 11 | C/D | OUT | Control/Data | 12 | I/O | OUT | Input/Output | 13 | GND | ------ | Ground | 14 | DB0 | IN/OUT | Data Bus 0 | 15 | DB2 | IN/OUT | Data Bus 2 | 16 | DB4 | IN/OUT | Data Bus 4 | 17 | DB6 | IN/OUT | Data Bus 6 | 18 | PARITY | IN/OUT | Data Parity | 19 | GND | ------ | Ground | 20 | /ATN | IN | Attention | 21 | /MSG | OUT | Message | 22 | /ACK | IN | Acknowledge | 23 | BSY | IN/OUT | Busy | 24 | /REQ | OUT | Request | 25 | GND | ------ | Ground | Note: Direction is Device relative Bus (other Devices).
For more informations, references and sources go to
|