Reference and Sources: PCI=Peripheral Component Interconnect. CompactPCI is a version of PCI adapted for industrial and/or embedded applications. Since CompactPCI is based on PCI you should first refer to the PCI standard. This only explains the extensions CompactPCI specifies. NOT DRAWN YET (At the backplane) NOT DRAWN YET (At the device (card)) 7x47 PIN (IEC917 and IEC1076-4-101) CONNECTOR at the backplane. 7x47 PIN (IEC917 and IEC1076-4-101) CONNECTOR at the device (card). Pin | Name | Description | Z1 | GND | Ground | Z2 | GND | Ground | Z3 | GND | Ground | Z4 | GND | Ground | Z5 | GND | Ground | Z6 | GND | Ground | Z7 | GND | Ground | Z8 | GND | Ground | Z9 | GND | Ground | Z10 | GND | Ground | Z11 | GND | Ground | Z12 | KEY | Keyed (no pin) | Z13 | KEY | Keyed (no pin) | Z14 | KEY | Keyed (no pin) | Z15 | GND | Ground | Z16 | GND | Ground | Z17 | GND | Ground | Z18 | GND | Ground | Z19 | GND | Ground | Z20 | GND | Ground | Z21 | GND | Ground | Z22 | GND | Ground | Z23 | GND | Ground | Z24 | GND | Ground | Z25 | GND | Ground | Z26 | GND | Ground | Z27 | GND | Ground | Z28 | GND | Ground | Z29 | GND | Ground | Z30 | GND | Ground | Z31 | GND | Ground | Z32 | GND | Ground | Z33 | GND | Ground | Z34 | GND | Ground | Z35 | GND | Ground | Z36 | GND | Ground | Z37 | GND | Ground | Z38 | GND | Ground | Z39 | GND | Ground | Z40 | GND | Ground | Z41 | GND | Ground | Z42 | GND | Ground | Z43 | GND | Ground | Z44 | GND | Ground | Z45 | GND | Ground | Z46 | GND | Ground | Z47 | GND | Ground | | | | A1 | 5V | +5 VDC | A2 | TCK | Test Clock | A3 | INTA# | Interrupt A | A4 | BRSV | Bused Reserved (don't use) | A5 | BRSV | Bused Reserved (don't use) | A6 | REQ# | Request PCI transfer | A7 | AD(30) | Address/Data 30 | A8 | AD(26) | Address/Data 26 | A9 | C/BE(3)# | Command: Byte Enable | A10 | AD(21) | Address/Data 21 | A11 | AD(18) | Address/Data 18 | A12 | KEY | Keyed (no pin) | A13 | KEY | Keyed (no pin) | A14 | KEY | Keyed (no pin) | A15 | 3.3V | +3.3 VDC | A16 | DEVSEL# | Device Select | A17 | 3.3V | +3.3 VDC | A18 | SERR# | System Error | A19 | 3.3V | +3.3 VDC | A20 | AD(12) | Address/Data 12 | A21 | 3.3V | +3.3 VDC | A22 | AD(7) | Address/Data 7) | A23 | 3.3V | +3.3 VDC | A24 | AD(1) | Address/Data 1) | A25 | 5V | +5 VDC | A26 | CLK1 | Clock ?? MHz | A27 | CLK2 | Clock ?? MHz | A28 | CLK4 | Clock ?? MHz | A29 | V(I/O) | +3.3 VDC or +5 VDC | A30 | C/BE(5)# | Command: Byte Enable | A31 | AD(63) | Address/Data 63 | A32 | AD(59) | Address/Data 59 | A33 | AD(56) | Address/Data 56 | A34 | AD(52) | Address/Data 52 | A35 | AD(49) | Address/Data 49 | A36 | AD(45) | Address/Data 45 | A37 | AD(42) | Address/Data 42 | A38 | AD(38) | Address/Data 38 | A39 | AD(35) | Address/Data 35 | A40 | BRSV | Bused Reserved (don't use) | A41 | BRSV | Bused Reserved (don't use) | A42 | BRSV | Bused Reserved (don't use) | A43 | USR | User Defined | A44 | USR | User Defined | A45 | USR | User Defined | A46 | USR | User Defined | A47 | USR | User Defined | | | | B1 | -12V | -12 VDC | B2 | 5V | +5 VDC | B3 | INTB# | Interrupt B | B4 | GND | Ground | B5 | BRSV | Bused Reserved (don't use) | B6 | GND | Ground | B7 | AD(29) | Address/Data 29 | B8 | GND | Ground | B9 | IDSEL | Initialization Device Select | B10 | GND | Ground | B11 | AD(17) | Address/Data 17 | B12 | KEY | Keyed (no pin) | B13 | KEY | Keyed (no pin) | B14 | KEY | Keyed (no pin) | B15 | FRAME# | Address or Data phase | B16 | GND | Ground | B17 | SDONE | Snoop Done | B18 | GND | Ground | B19 | AD(15) | Address/Data 15 | B20 | GND | Ground | B21 | AD(9) | Address/Data 9) | B22 | GND | Ground | B23 | AD(4) | Address/Data 4) | B24 | 5V | +5 VDC | B25 | REQ64# | | B26 | GND | Ground | B27 | CLK3 | Clock ?? MHz | B28 | GND | Ground | B29 | BRSV | Bused Reserved (don't use) | B30 | GND | Ground | B31 | AD(62) | Address/Data 62 | B32 | GND | Ground | B33 | AD(55) | Address/Data 55 | B34 | GND | Ground | B35 | AD(48) | Address/Data 48 | B36 | GND | Ground | B37 | AD(41) | Address/Data 41 | B38 | GND | Ground | B39 | AD(34) | Address/Data 34 | B40 | GND | Ground | B41 | BRSV | Bused Reserved (don't use) | B42 | GND | Ground | B43 | USR | User Defined | B44 | USR | User Defined | B45 | USR | User Defined | B46 | USR | User Defined | B47 | USR | User Defined | | | | C1 | TRST# | Test Logic Reset | C2 | TMS | Test Mode Select | C3 | INTC# | Interrupt C | C4 | V(I/O) | +3.3 VDC or +5 VDC | C5 | RST | Reset | C6 | 3.3V | +3.3 VDC | C7 | AD(28) | Address/Data 28 | C8 | V(I/O) | +3.3 VDC or +5 VDC | C9 | AD(23) | Address/Data 23 | C10 | 3.3V | +3.3 VDC | C11 | AD(16) | Address/Data 16 | C12 | KEY | Keyed (no pin) | C13 | KEY | Keyed (no pin) | C14 | KEY | Keyed (no pin) | C15 | IRDY# | Initiator Ready | C16 | V(I/O) | +3.3 VDC or +5 VDC | C17 | SBO# | Snoop Backoff | C18 | 3.3V | +3.3 VDC | C19 | AD(14) | Address/Data 14 | C20 | V(I/O) | +3.3 VDC or +5 VDC | C21 | AD(8) | Address/Data 8) | C22 | 3.3V | +3.3 VDC | C23 | AD(3) | Address/Data 3) | C24 | V(I/O) | +3.3 VDC or +5 VDC | C25 | BRSV | Bused Reserved (don't use) | C26 | REQ1# | Request PCI transfer | C27 | SYSEN# | | C28 | GNT3# | Grant | C29 | C/BE(7) | Command: Byte Enable | C30 | V(I/O) | +3.3 VDC or +5 VDC | C31 | AD(61) | Address/Data 61 | C32 | V(I/O) | +3.3 VDC or +5 VDC | C33 | AD(54) | Address/Data 54 | C34 | V(I/O) | +3.3 VDC or +5 VDC | C35 | AD(47) | Address/Data 47 | C36 | V(I/O) | +3.3 VDC or +5 VDC | C37 | AD(40) | Address/Data 40 | C38 | V(I/O) | +3.3 VDC or +5 VDC | C39 | AD(33) | Address/Data 33 | C40 | FAL# | Power Supply Status FAL (CompactPCI specific) | C41 | DEG# | Power Supply Status DEG (CompactPCI specific) | C42 | PRST# | Push Button Reset (CompactPCI specific) | C43 | USR | User Defined | C44 | USR | User Defined | C45 | USR | User Defined | C46 | USR | User Defined | C47 | USR | User Defined | | | | D1 | +12V | +12 VDC | D2 | TDO | Test Data Output | D3 | 5V | +5 VDC | D4 | INTP | | D5 | GND | Ground | D6 | CLK | | D7 | GND | Ground | D8 | AD(25) | Address/Data 25 | D9 | GND | Ground | D10 | AD(20) | Address/Data 20 | D11 | GND | Ground | D12 | KEY | Keyed (no pin) | D13 | KEY | Keyed (no pin) | D14 | KEY | Keyed (no pin) | D15 | GND | Ground | D16 | STOP# | Stop transfer cycle | D17 | GND | Ground | D18 | PAR | Parity for AD0-31 & C/BE0-3 | D19 | GND | Ground | D20 | AD(11) | Address/Data 11 | D21 | M66EN | | D22 | AD(6) | Address/Data 6) | D23 | 5V | +5 VDC | D24 | AD(0) | Address/Data 0) | D25 | 3.3V | +3.3 VDC | D26 | GNT1# | Grant | D27 | GNT2# | Grant | D28 | REQ4# | Request PCI transfer | D29 | GND | Ground | D30 | C/BE(4)# | Command: Byte Enable | D31 | GND | Ground | D32 | AD(58) | Address/Data 58 | D33 | GND | Ground | D34 | AD(51) | Address/Data 51 | D35 | GND | Ground | D36 | AD(44) | Address/Data 44 | D37 | GND | Ground | D38 | AD(37) | Address/Data 37 | D39 | GND | Ground | D40 | REQ5# | Request PCI transfer | D41 | GND | Ground | D42 | REQ6# | Request PCI transfer | D43 | USR | User Defined | D44 | USR | User Defined | D45 | USR | User Defined | D46 | USR | User Defined | D47 | USR | User Defined | | | | E1 | 5V | +5 VDC | E2 | TDI | Test Data Input | E3 | INTD# | Interrupt D | E4 | INTS | | E5 | GNT# | Grant | E6 | AD(31) | Address/Data 31 | E7 | AD(27) | Address/Data 27 | E8 | AD(24) | Address/Data 24 | E9 | AD(22) | Address/Data 22 | E10 | AD(19) | Address/Data 19 | E11 | C/BE(2)# | Command: Byte Enable | E12 | KEY | Keyed (no pin) | E13 | KEY | Keyed (no pin) | E14 | KEY | Keyed (no pin) | E15 | TRDY# | Target Ready | E16 | LOCK# | Lock resource | E17 | PERR# | Parity Error | E18 | C/BE(1)# | Command: Byte Enable | E19 | AD(13) | Address/Data 13 | E20 | AD(10) | Address/Data 10 | E21 | C/BE(0)# | Command: Byte Enable | E22 | AD(5) | Address/Data 5) | E23 | AD(2) | Address/Data 2) | E24 | ACK64# | | E25 | 5V | +5 VDC | E26 | REQ2# | Request PCI transfer | E27 | REQ3# | Request PCI transfer | E28 | GNT4# | Grant | E29 | C/BE(6)# | Command: Byte Enable | E30 | PAR64 | | E31 | AD(60) | Address/Data 60 | E32 | AD(57) | Address/Data 57 | E33 | AD(53) | Address/Data 53 | E34 | AD(50) | Address/Data 50 | E35 | AD(46) | Address/Data 46 | E36 | AD(43) | Address/Data 43 | E37 | AD(39) | Address/Data 39 | E38 | AD(36) | Address/Data 36 | E39 | AD(32) | Address/Data 32 | E40 | GNT5# | Grant | E41 | BRSV | Bused Reserved (don't use) | E42 | GNT6# | Grant | E43 | USR | User Defined | E44 | USR | User Defined | E45 | USR | User Defined | E46 | USR | User Defined | E47 | USR | User Defined | | | | F1 | GND | Ground | F2 | GND | Ground | F3 | GND | Ground | F4 | GND | Ground | F5 | GND | Ground | F6 | GND | Ground | F7 | GND | Ground | F8 | GND | Ground | F9 | GND | Ground | F10 | GND | Ground | F11 | GND | Ground | F12 | KEY | Keyed (no pin) | F13 | KEY | Keyed (no pin) | F14 | KEY | Keyed (no pin) | F15 | GND | Ground | F16 | GND | Ground | F17 | GND | Ground | F18 | GND | Ground | F19 | GND | Ground | F20 | GND | Ground | F21 | GND | Ground | F22 | GND | Ground | F23 | GND | Ground | F24 | GND | Ground | F25 | GND | Ground | F26 | GND | Ground | F27 | GND | Ground | F28 | GND | Ground | F29 | GND | Ground | F30 | GND | Ground | F31 | GND | Ground | F32 | GND | Ground | F33 | GND | Ground | F34 | GND | Ground | F35 | GND | Ground | F36 | GND | Ground | F37 | GND | Ground | F38 | GND | Ground | F39 | GND | Ground | F40 | GND | Ground | F41 | GND | Ground | F42 | GND | Ground | F43 | GND | Ground | F44 | GND | Ground | F45 | GND | Ground | F46 | GND | Ground | F47 | GND | Ground | Overview:A CompactPCI system is composed of up to eight CompactPCI card locations: - One System Slot
- Up to seven Peripheral Slots
The connector has 7 columns with 47 rows. They are divided into groups: - Row 1-25: 32-bit PCI
- Row 26-47: Additional pins for 64-bit PCI (System Slot boards must use it).
- Row 26-28 and 40-42: Primarily implemented on System Slot boards.
The following signals must be terminated: - AD0-31
- C/BE0#-C/BE3#
- PAR
- FRAME#
- IRDY#
- TRDY#
- STOP#
- LOCK#
- IDSEL
- DEVSEL#
- PERR#
- SERR#
- RST#
The following signals must be terminated if used: - INTA#
- INTB#
- INTC#
- INTD#
- SB0#
- SDOBE
- AD32-AD63
- C/BE4#-C/BE7#
- REQ64#
- ACK64#
- PAR64#
The following signals do no require a stub termination: - CLK
- REQ#
- GNT#
- TDI#
- TDO
- TCK
- TMS
- TRST#
The System Slot board must pullup the following signals (even if not used): Connector: 1 | GND | 5V | -12V | TRST# | 12V | 5V | GND | 2 | GND | TCK | 5V | TMS | DO | TDI | GND | 3 | GND | INTA# | INTB# | INTC# | 5V | INTD# | GND | 4 | GND | BRSV | GND | V(I/O) | INTP | INTS | GND | 5 | GND | BRSV | BRSV | RST | GND | GNT# | GND | 6 | GND | REQ# | GND | 3.3V | CLK | AD(31) | GND | 7 | GND | AD(30) | AD(29) | AD(28) | GND | AD(27) | GND | 8 | GND | AD(26) | GND | V(I/O) | AD(25) | AD(24) | GND | 9 | GND | C/BE(3)# | IDSEL | AD(23) | GND | AD(22) | GND | 10 | GND | AD(21) | GND | 3.3V | AD(20) | AD(19) | GND | 11 | GND | AD(18) | AS(17) | AD(16) | GND | C/BE(2)# | GND | 12 | KEY | KEY | KEY | KEY | KEY | KEY | KEY | 13 | KEY | KEY | KEY | KEY | KEY | KEY | KEY | 14 | KEY | KEY | KEY | KEY | KEY | KEY | KEY | 15 | GND | 3.3V | FRAME# | IRDY# | GND | TRDY# | GND | 16 | GND | DEVSEL# | GND | V(I/O) | STOP# | LOCK# | GND | 17 | GND | 3.3V | SDONE | SBO# | GND | PERR# | GND | 18 | GND | SERR# | GND | 3.3V | PAR | C/BE(1)# | GND | 19 | GND | 3.3V | AD(15) | AD(14) | GND | AD(13) | GND | 20 | GND | AD(12) | GND | V(I/O) | AD(11) | AD(10) | GND | 21 | GND | 3.3V | AD(9) | AD(8) | M66EN | C/BE(0)# | GND | 22 | GND | AD(7) | GND | 3.3V | AD(6) | AD(5) | GND | 23 | GND | 3.3V | AD(4) | AD(3) | 5V | AD(2) | GND | 24 | GND | AD(1) | 5V | V(I/O) | AD(0) | ACK64# | GND | 25 | GND | 5V | REQ64# | BRSV | 3.3V | 5V | GND | 26 | GND | CLK1 | GND | REQ1# | GNT1# | REQ2# | GND | 27 | GND | CLK2 | CLK3 | SYSEN# | GNT2# | REQ3# | GND | 28 | GND | CLK4 | GND | GNT3# | REQ4# | GNT4# | GND | 29 | GND | V(I/O) | BRSV | C/BE(7 ) | GND | C/BE(6)# | GND | 30 | GND | C/BE(5)# | GND | V(I/O) | C/BE(4)# | PAR64 | GND | 31 | GND | AD(63) | AD(62) | AD(61) | GND | AD(60) | GND | 32 | GND | AD(59) | GND | V(I/O) | AD(58) | AD(57) | GND | 33 | GND | AD(56) | AD(55) | AD(54) | GND | AD(53) | GND | 34 | GND | AD(52) | GND | V(I/O) | AD(51) | AD(50) | GND | 35 | GND | AD(49) | AD(48) | AD(47) | GND | AD(46) | GND | 36 | GND | AD(45) | GND | V(I/O) | AD(44) | AD(43) | GND | 37 | GND | AD(42) | AD(41) | AD(40) | GND | AD(39) | GND | 38 | GND | AD(38) | GND | V(I/O) | AD(37) | AD(36) | GND | 39 | GND | AD(35) | AD(34) | AD(33) | GND | AD(32) | GND | 40 | GND | BRSV | GND | FAL# | REQ5# | GNT5# | GND | 41 | GND | BRSV | BRSV | DEG# | GND | BRSV | GND | 42 | GND | BRSV | GND | PRST# | REQ6# | GNT6# | GND | 43 | GND | USR | USR | USR | USR | USR | GND | 44 | GND | USR | USR | USR | USR | USR | GND | 45 | GND | USR | USR | USR | USR | USR | GND | 46 | GND | USR | USR | USR | USR | USR | GND | 47 | GND | USR | USR | USR | USR | USR | GND | | Z | A | B | C | D | E | F | Signal Descriptions:PRSTPush Button Reset. DEGPower Supply Status DEG FALPower Supply Status FAL SYSENSystem Slot Identification For more information seePCI Notes
|